Think you’re safe from cardiac arrest in a hospital? Think again
Think you’re safe from cardiac arrest in a hospital? Think again
Response times reduced from 10 minutes to two
Your employees probably think they’re much safer and closer to medical assistance in case of emergency than employers in the corporate setting, and as a rule, of course, they’re right. However, if they (and you) assume that this rule readily applies to sudden cardiac arrest (SCA), you may be in for a rude awakening. For as one hospital in Providence, RI, discovered, there’s always room for improvement — and some hospitals may be missing the boat when it comes to ensuring that employees and patients have the most effective procedures in place for these emergencies.
Ten years ago, the typical time from discovering the victim to initial shock at The Miriam Hospital was between seven to 10 minutes; today, it’s about two minutes. The difference? Today, there are 22 automated external defibrillators (AEDs) at Miriam, and every nurse on staff is trained in their use as a first responder.
Are hospital setting AEDs redundant?
The idea of AEDs on airplanes and at large public events seems like good common sense, but wouldn’t they be a bit redundant in a hospital setting? Not at all, insists Sandy Sawyer-Silva, RN, MSN, CCRN, nurse manager of the intensive care unit at Miriam. "An AED is, in fact, not redundant in a hospital — it’s a first-line device for SCAs," she asserts. "It is estimated that between 85% - 90% of all sudden cardiac death is due to shockable rhythms, so the faster you can get the device to a patient and shock them, the greater the likelihood of survival."
The literature seems to bear her out. Here are just a few examples:
• Only 15% of victims of SCA in hospitals survive to be discharged, largely because lifesaving defibrillation therapy does not reach them in time.
• SCA survival rates approach 90% in coronary care units, which are typically well equipped with manual defibrillators and highly skilled operators.
• Each minute of delay between the onset of an arrest to defibrillation decreases the chance for survival by 10%.
• Defibrillation delays in hospitals can be attributed to outmoded hospital protocols that require nurses — often the first to respond to a patient in distress — to administer CPR, then call for the defibrillation team, and wait. 4
"About 15 years ago, we did a time study and looked at how long it took us to deliver the first shock," recalls Sawyer-Silva. "We were stunned to find that even nurses and residents trained in advanced cardiac life support took seven to 10 minutes to get off the first shock — and this is a small hospital (242 beds) where you don’t have to go very far. With AEDs, we can successfully and repeatedly get three successive shocks off in less than two minutes from the time the person is found."
The Miriam currently uses the Agilent Heartstream FR2, manufactured by Palo Alto, CA-based Agilent Technologies. "It’s a new model we’ve had for the past six months," notes Sawyer-Silva. They are present throughout the hospital, on every medical surgical unit, in the clinic, and in the outpatient operating room in the building across the street.
"Every nurse knows how to use them; they’re very simple to use, designed, in fact, for use by nonhealth care individuals," says Sawyer-Silva. "It does everything but walk the dog."
The device is applied to patients who meet three criteria — there is no pulse, they are not breathing, and they are otherwise completely unresponsive. "Once that’s established, you push the on-off’ button," Sawyer-Silva explains. "Then, the device will tell you to attach electrodes to the patient’s bare chest; diagrams on the electrodes show you where to apply them. Literally, a 10-year-old could do it. Once that’s done, the AED will tell you to plug the pads into the flashing yellow lights on the device. Then it will say, Analyzing heart rhythm, do not touch patient.’ All this takes about 15 seconds. If it detects a rhythm, it can’t shock, it tells you to check the patient, who may now a have pulse. If not, you proceed with CPR. Or, the machine will say Shock advised, push orange button.’ Immediately after the patient is shocked, the device reassesses, tells you to stand back, and will deliver up to three shocks." All the shocks, she notes, are 150 joules, rather than successively stronger. "Older devices did that, but this is more advanced technology," she explains.
All nurses who join Miriam are trained in the use of the AED as part of their orientation. In fact, all health care providers — physical and respiratory therapists, nuclear medicine technicians, and so forth — have to take health care provider CPR, which includes use of the AEDs. Anyone so trained can be a first responder. There is no need for inservice follow-up, says Sawyer-Silva. "We did a retention study a few years ago, and nurses were able to use the device within three to six months without any additional training," she says.
A real believer’
Sawyer-Silva is firmly convinced the AEDs have saved many lives that might otherwise have been lost. "Each minute before arrest is recognized represents another 10% likelihood of not surviving," she notes. "So, if we’re there in two minutes, that increases the likelihood of survival to 80%. I’m a real believer in this." She estimates the AEDs are applied at Miriam approximately 20 times a month.
The hospital’s original AEDs were provided by Laerdal Co., a Swedish distributor that was later acquired by Agilent. "But we looked at all the brands that are available today — and there are many," she says. "Our team chose the Heartstream FR2 because they thought it was the simplest to use and had features they wanted. The size was right; the directions were clear; all the features were superior. We believe that simplicity absolutely reduces time to application. The less time you have to think about things, the better it is — especially in a stressful situation."
[For more information, contact: Sandy Sawyer-Silva, RN, MSN, CCRN, The Miriam Hospital, 164 Summit Ave., Providence, RI 02906. Telephone: (401) 793-3520.]
References
1. American Journal of Critical Care; 1998.
2. Carruth JE, Silverman ME. Ventricular fibrillation complicating acute myocardial infarction: Reasons against the routine use of lidocaine. Am Heart J 1982; 104:545-50.
3. Cummin RO, et al. Ann Emerg Med, 1989; 18:1269-75.
4. Kaye W, et al. Resuscitation, 1995; 30:151-56.
Subscribe Now for Access
You have reached your article limit for the month. We hope you found our articles both enjoyable and insightful. For information on new subscriptions, product trials, alternative billing arrangements or group and site discounts please call 800-688-2421. We look forward to having you as a long-term member of the Relias Media community.